Mirror reflex optics with a 15° field of view and a sharply defined 1° measuring circle for precise targeting Focusing mechanism for accurate spot measurements across multiple clinical applications Optional close-up lenses allow measurement distances as short as 34 cm Optional photometric probe enables direct luminance measurement on monitor screens Silicon sensor with color correction, matching human eye sensitivity for accurate, correction-free readings Class B luminance meter compliance, ensuring regulatory accuracy and reliability Memory capacity for 1,000 measurement values, organized into 10 groups for structured test management On-device keypad and display for immediate data review and processing Built-in USB connectivity for seamless transfer of measurement results to PC with included analysis software (Generated by AI)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Send out for annual re-certification.
High-turnover; keep spares.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →