GEMSS · Model Spinel 3G
Compact Design with highly compact design for improved mobility and a powerful 12KW HF generator Camera, X-ray & Orbital Rotation High-dynamic high resolution CCD camera High performance rotating Anode X-ray tube Larger 800mm free space and extended 135° (90° – 45° ) orbital rotation for simplified positioning High Quality Imaging Wide exposure range(0.2~10mA) Improved penetration of dense anatomy with Boost mode (up to 20 mA) Pulse technology supports 30 FPS (frames / sec) for more precise operation Smart ABC (Auto Brightness Control) Optimized Workflow Intuitive pictographic UI on Touch-screen OP panel Additional sub-handles for enhanced mobility Compact design provides more free space for operation Motorized cart elevation for easier monitor viewing Extended time and multi-frame recording capability Multi-speed (1,2,4,8,15,25 frames/sec) Database Management Improved penetration of dense anatomy with Boost mode (up to 20 mA) Manage patient information Before & after surgery comparison Versatile Diagnostic Tools Zoom, contrast, reverse, invert Filtering, edge enhancement Annotation Unlimited patient capacity Unlimited study images PACS Connectivity With DICOM 3.0 Store and print Modality worklist management MPPS Storage commitment Import & export.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No image on boost, exposure inhibited, kV/mA error, image too dark or bright.
Root cause: X-ray tube / monoblock fault, HV generator fault, or the AEC / dose-control loop.
Symptoms: Dim, distorted, vignetted or noisy image; dead lines (flat panel); S-distortion (II).
Root cause: Image-intensifier tube ageing / II fault, or a flat-panel detector fault.
Symptoms: Orbital, lateral or vertical motion binds, drifts, or a brake will not hold.
Root cause: Worn friction brakes, bearings, or the counterbalance.
Symptoms: No image on one or both monitors, image freeze, no last-image-hold.
Root cause: Monitor, the cart-to-stand cable, or the image-processing PC.
Symptoms: Fluoro inhibited after a run, tube-heat warning.
Root cause: Monoblock heat limit reached or a cooling-fan fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube / monoblock | Major service part | $$$$ | Expert-level |
| Image intensifier tube / camera | Major service part | $$$$ | Difficult |
| Flat-panel detector (if fitted) | Major service part | $$$$ | Difficult |
| C-arm friction-brake / bearing kit | Major service part | $$ | Moderate |
| Monitor / video cable | Major service part | $$ | Fairly easy |
| Cooling fan | Periodic replacement | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.