GE HealthCare · Model Signa Vibrant 1.5T
Lays the foundation for a complete solution with a superior combination of high spatial detail and scanning speed. Uses the GE exclusive GEM acceleration technique to further accelerate the scanning speed of GE's patent pending VIBRANT technique. With VIBRANT-XV users can acquire higher resolution faster. VIBRANT-XV still allows the choice of direct sagittal or axial imaging making it easy for users to satisfy clinicians, and automatically optimizes parameters making it easy for user technologists to give users consistent image quality. Collects two echoes with water and fat, spins in- and out-of-phase and utilizes a two-point Dixon technique to synthesize water and fat images. Vibrant-Flex optimizes acquisition with a high signal-to-noise ratio (SNR) for acquiring high quality water and fat images. This capability lets the user prescribe thinner slices for high spatial resolution imaging. Image both breasts in high resolution in one patient visit. Perform a bilateral breast exam in both the sagittal and axial planes with the same resolution and scan time as a single-breast MR study. Obtain high temporal resolution without sacrificing spatial resolution. Eliminate fat with absolute reliability and confidence. Utilize the bilateral breast imaging technique that is the most sensitive to their patients' diagnostic needs. Perform procedures that can have a positive economic impact on their practice. Enhances diagnostic confidence by improving the ability to characterize lesions and monitor response to therapy. It is a breast-specific, single-voxel spectroscopy application designed for ease-of-use and enhanced visualization. A single voxel spectroscopy technique that has been designed specifically for the breast. It is designed to enhance their diagnostic confidence and uses an optimized signal detection technique to reliably visualize the presence, or absence, of a choline peak. In addition, BREASE is easy to use – the technologist simply places the voxel over the area of interest. The Vanguard Breast Table developed and sold by Sentinelle Medical - is a unique solution with a Variable Coil Geometry (VCG) for optimal positioning of coil elements. HD Breast Array provides approximately 30% more SNR than exams done without the HD Breast Array, enhancing the performance of VIBRANT and providing excellent lateral and medial access for biopsy procedures. 8-channel HD Breast Array 8-channel, 8-element phased array design Optimized for parallel imaging techniques Biopsy compatible for both medical and lateral approaches PURE compatible CADStream by Confirmation automatically generates the post-processed series and helps identify the most suspicious washout curves. Sureloc, included with CADstream, enables productive planning of MR-guided biopsies from the console.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Low signal-to-noise, shading, or a dead region in images; coil not detected or fails the coil check.
Root cause: Damaged RF coil element, a coil-cable / connector fault, or a preamp fault.
Symptoms: Geometric distortion, gradient-amplifier faults, acoustic change, over-temperature trips.
Root cause: Gradient-amplifier fault, gradient-coil cooling problem, or a gradient-coil fault.
Symptoms: Rising helium boil-off, cold-head noise or stall, He level dropping, compressor alarms.
Root cause: Cold-head at end of life, a helium-compressor fault, or a chilled-water problem.
Symptoms: System-cooling alarms, gradient or RF over-temperature, scans aborting.
Root cause: Facility chilled-water supply, the heat exchanger, or internal pumps.
Symptoms: Table will not dock, drive or index; landmarking errors.
Root cause: Table drive, docking sensor, or encoder fault.
Symptoms: Recon errors, host hangs, images will not reach PACS.
Root cause: Recon or host computer fault, or the network / storage.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Planned replacement; He boil-off rises as it wears.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| RF receive coil (exchange) | Major service part | $$$$ | Moderate |
| Cold head Planned replacement; He boil-off rises as it wears. | Periodic replacement | $$$$ | Difficult |
| Helium compressor / adsorber | Major service part | $$$$ | Difficult |
| Gradient amplifier module | Major service part | $$$$ | Expert-level |
| Chilled-water pump / heat exchanger | Major service part | $$$ | Difficult |
| Patient table drive / encoder | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.