
GE HealthCare · Model Discovery MR750w GEM
MultiDrive RF Transmit Fully automated and independent RF pulse amplitude and phase control produce consistently clear 3.0T images OpTix Optical RF Offers high channel count, analog to digital-optical signal conversion where it matters - inside the scan room to minimize noise and signal degradation, but away from the patient A large usable field of view is needed to properly image off-center anatomy such as a shoulder or hip. So the Discovery* MR750w features a 70 cm flared, open bore design with a large 50 x 50 x 50 cm field of view Gradients and RF body coils are water and air-cooled for optimum duty-cycle performance, short repetition time (TR) and echo time (TE), producing sharp and clear images The GEM Suite of flexible coils embrace the patient, bringing both function and comfort while helping to minimize anxiety and motion during the exam. Intuitive applications help clinicians utilize the full potential of 3.0T MR imaging.
Intended use: MultiDrive RF Transmit Fully automated and independent RF pulse amplitude and phase control produce consistently clear 3.0T images OpTix Optical RF Offers high channel count, analog to digital-optical signal conversion where it matters—inside the scan room to minimize noise and signal degradation, but away from the patient A large usable field of view is needed to properly image off-center anatomy such as a shoulder or hip. So the Discovery* MR750w features a 70 cm flared, open bore design with a large 50 x 50 x 50 cm field of view Gradients and RF body coils are water and air-cooled for optimum duty-cycle performance, short repetition time (TR) and echo time (TE), producing sharp and clear images The GEM Suite of flexible coils embrace the patient, bringing both function and comfort while helping to minimize anxiety and motion during the exam. Intuitive applications help clinicians utilize the full potential of 3.0T MR imaging.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Low signal-to-noise, shading, or a dead region in images; coil not detected or fails the coil check.
Root cause: Damaged RF coil element, a coil-cable / connector fault, or a preamp fault.
Symptoms: Geometric distortion, gradient-amplifier faults, acoustic change, over-temperature trips.
Root cause: Gradient-amplifier fault, gradient-coil cooling problem, or a gradient-coil fault.
Symptoms: Rising helium boil-off, cold-head noise or stall, He level dropping, compressor alarms.
Root cause: Cold-head at end of life, a helium-compressor fault, or a chilled-water problem.
Symptoms: System-cooling alarms, gradient or RF over-temperature, scans aborting.
Root cause: Facility chilled-water supply, the heat exchanger, or internal pumps.
Symptoms: Table will not dock, drive or index; landmarking errors.
Root cause: Table drive, docking sensor, or encoder fault.
Symptoms: Recon errors, host hangs, images will not reach PACS.
Root cause: Recon or host computer fault, or the network / storage.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Planned replacement; He boil-off rises as it wears.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| RF receive coil (exchange) | Major service part | $$$$ | Moderate |
| Cold head Planned replacement; He boil-off rises as it wears. | Periodic replacement | $$$$ | Difficult |
| Helium compressor / adsorber | Major service part | $$$$ | Difficult |
| Gradient amplifier module | Major service part | $$$$ | Expert-level |
| Chilled-water pump / heat exchanger | Major service part | $$$ | Difficult |
| Patient table drive / encoder | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could exceed IEC60601-2-33 limit of 3.2 W/kg for some scans.
At certain sites, the MRU may not be connected to the magnet. In emergency situations, a disconnected MRU could delay removal of a ferrous object from the magnet, potentially resulting in life-threatening injuries. The MRU must be connected to the magnet at all times.
Failure to properly document the CTDI in the Technical Reference or User Manual.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio