GE HealthCare · Model Brivo XR285amx
The Brivo XR285amx is a self-contained battery operated mobile X-Ray imaging system designed for performing radiographic exams at the point of care when it is not safe or practical to move the patient to the radiographic room. Brivo XR285amx is suited for routine radiographic procedures within a hospital including radiology departments, intensive care units, cardiac care units, emergency departments, operating rooms, orthopedics, pediatrics, hospital rooms and clinics. Key technology features include: • Designed to be used with conventional film or CR cassettes. • Designed for 24/7 availability. Use with battery or make exposures while the unit is charging. • Automatic charging algorithms allow the system to be re-charged even if batteries are not fully drained. • Average system charge time of 3 hours. • Choose your generator power with 15kW (nominal) generator or the 30kW (nominal) option. • System can be driven within 4 seconds of activation.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
An issue was identified with the mAs accuracy check performed on the system that could result in inaccuracies in the 10% to 20% range for exposure times longer than 15 msec.