Famed Zywiec · Model LM-01.3
• Construction of the bed is made of steel profiles covered with powder varnish and ABS plastic moulds • Back rest inclination angle and height adjustment are realized by electric actuators (24 V DC) controlled by control panels on side rails, central control panel and foot controller • Trendelenburg and reverse Trendelenburg positions are regulated by interlocking gas springs • Back rest with CPR function • Control system with battery • Wall fenders mounted on the bed corners in the head part of the bed • Leg segment can be pulled under the seat segment • Detachable foot and head boards • Wheels with a central blockade and with one directional wheel • Bed is equipped with: set of mattresses (two mattresses of bed frame and one for a new-born baby), foot rests, hand grip, knee rests WS-05.6, stainless steel bowl, drip bottle holder
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Short runtime, low-battery alarm.
Root cause: Aged battery.
Symptoms: Intermittent signal/power.
Root cause: Repeated flexing.
Symptoms: Loose device, vibration damage.
Root cause: Docking latch wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical for transport; spares mandatory.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Docking cradle / latch | Periodic replacement | $$ | Fairly easy |
| Patient cable set | Periodic replacement | $$ | Easy |
| Rechargeable battery pack Critical for transport; spares mandatory. | Frequent wear item | $$$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.