Esaote · Model MyLab 70XVG
Quality: Providing impressive image quality in all modalities and applications, delivering well-balanced systems, which integrate the latest technologies to consistently ensure the highest level of diagnosis. Flexibility: Having the capability to fit perfectly into every medical environment, offering dedicated solutions to every single application and satisfying the needs of every unique operator. Workflow: Thinking of the operator as the most important factor in the system’s design has resulted in ergonomics and fast user-interface to increase users’ comfort and clinical efficiency. Value: Offering exactly what the operator needs and broadening the number of possible users through a flexible and modular architecture enhances the value of investment and the diagnostic capability of every user Impressive Image Quality: A new standard of image quality in all modalities and a wide range of applications, including standard cardiology, advanced cardiology and vascular. Advanced Architecture: Based on the most updated electronic and informatics architecture, and able to manage even the most recent developments in signal processing and treatment. Software-Based Updating: Due to sophisticated architecture, continuous technological evolution in the medical field can be available to the users merely through software upgrades. Specific upgrade kits can easily improve the performance of the MyLab™systems and enable new functions or technologies, always ensuring the most updated diagnostic capability. Easy And Fast Interfacing: The MyLab™Gold Platform translates the potential of informatics into consistent clinical values. Sophisticated calculations and post-processing elaborations are normally performed on powerful workstations, which is why the MyLab™Gold Platform has been designed with unlimited capabilities in data transferring and sharing. Unique Versatility: The MyLab™Gold Platform allows systems to continuously evolve, ensuring that system configurations are always updated and satisfying the most demanding clinical environments. This guarantees the value of the investment into the future.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy, low-contrast or non-uniform image, missing sector, drop-out that follows the system not the probe.
Root cause: Front-end / beamformer board fault, a probe-port (connector) board fault, or a system-board fault.
Symptoms: A probe works on one port but not another, or is not detected at all.
Root cause: Worn probe-port connector or a scan-connector board fault.
Symptoms: Dead system, hangs at boot, or powers off under load.
Root cause: Power supply / DC converter, the system battery, or a system-board fault.
Symptoms: Unresponsive TGC sliders or keys, distorted or blank display.
Root cause: Control-panel board, touchscreen, or the monitor.
Symptoms: Thermal-shutdown warning, fan roar, hot exhaust.
Root cause: Failed or dust-clogged cooling fan or blocked air path.
Symptoms: Studies will not send to PACS, images will not archive, worklist empty.
Root cause: Network configuration or a storage-drive fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Front-end / beamformer board | Major service part | $$$$ | Difficult |
| Probe-port / scan-connector board | Major service part | $$$ | Difficult |
| Power supply / DC converter | Major service part | $$$ | Difficult |
| Control-panel / touchscreen assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
| System hard drive | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
The probe power monitoring settings have been found to be not appropriate under specific operating conditions when connected to the devices listed below. This issue may result in overheating of the probe head. The probe power monitoring settings may not be effective in specific operating conditions so that the surface of the probe head may overheat in around one minute of continuous operations. The patient may experience discomfort, reddening of epidermis and/or mild pain. To date, no patient injury has been reported with regards to this issue.
The ultrasound system used in certain settings may result in overheating of the ultrasound probe head.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio