EPPENDORF · Model Thermomixer R
• 10 interchangeable thermoblocks to cover tubes from 0.2 mL to 50 mL as well as plates and glass slides • Wide temperature range and high temperature accuracy due to active heating and cooling capability from 13°C below RT to 99°C • Adjustable mixing speed from 300 to 1,500 rpm for gentle or vigorous mixing • Dry incubation technology eliminates contamination risk associated with classical waterbath incubation • Insulated thermoblocks for ergonomic operation - you won’t burn your fingers • Automatic thermoblock recognition properly sets speed and temperature ranges for each block • 10 interchangeable thermoblocks to cover tubes from 0.2 mL to 50 mL as well as plates and glass slides • Wide temperature range and high temperature accuracy due to active heating and cooling capability from 13°C below RT to 99°C • Adjustable mixing speed from 300 to 1,500 rpm for gentle or vigorous mixing • Dry incubation technology eliminates contamination risk associated with classical waterbath incubation • Insulated thermoblocks for ergonomic operation - you won’t burn your fingers • Automatic thermoblock recognition properly sets speed and temperature ranges for each block
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Chamber out of set-point range, alarm.
Root cause: Heater element or sensor drift.
Symptoms: Gas concentration alarm, contamination risk.
Root cause: Gas sensor or solenoid valve wear.
Symptoms: Humidity drift, condensation.
Root cause: Aged door gasket.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket / seal | Periodic replacement | $ | Fairly easy |
| Temperature sensor | Periodic replacement | $$ | Moderate |
| CO2 sensor | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →