A stable, highly-adjustable ESU with TFT color touchscreen panel for easy, flexible operation. Internet connectivity and data logging capabilities. Patient return electrode monitor increases patient safety by preventing electrode site burns. Remote power settings allow clinicians to adjust mode and power from the sterile area. Data logging stores the last 50 surgical cases in system memory. System can run self-demonstration mode to display modes and settings. 100 different combinations of operating modes for virtually any procedure. Two Vessel Sealing Modes for up to 7mm of tissue, with audio indication at completion. Alarm sounds if vessels are improperly sealed. Monopolar and bipolar capable with the appropriate accessories. Automatic tissue sensing starts and stops bipolar modes without footswitch activation. Audible feedback after completion of Bipolar coag reduces charring and sticking. Two simultaneous coagulation outputs with independent controls. Self-diagnostic protocols help to ensure all parts and accessories are properly functioning.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →