Dräger · Model Infinity Trident NMT SmartPod
• Multiple measuring capabilities • Trident assesses neuromuscular blockade by monitoring thumb acceleration (twitch response) during electrical stimulation of a peripheral nerve • Single Twitch: single stimulus with a response compared to a reference Train-Of-Four (TOF): series of four impulses are given, results on TOF-ratio or TOF-count • Post-Tetanic Count: titanic stimulation, followed by single stimuli at one-second intervals is generated; the number of responses to the one second stimuli are counted • NMT data is valuable before, during and after anesthesia in the operating room, and also when mechanical ventilation is used in the intensive care unit • Monitoring NMT may help reduce the amount of neuromuscular blocking agents required during anesthesia, which could mean a shorter recovery period and a decrease in the post-operative incidence of neuromuscular weakness • Uses a standardized monitoring interface and alarm management feature • Quantifies the degree of muscle relaxation • Automatically integrates NMT parameters into the electronic patient record
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →