DK Medical · Model Prostar
Wide Free Space of SID 78cm Minimizing Dose by Pulsed Fluoroscopy and Half Dose Mode User-Friendly Design with Dual Monitor Fine Image Display through monitor 2.2kW Power PROSTAR features a compact and optimized design for easy operation with all the cables of components contained within the C-arm. Its light-weight body supports more smooth movements providing astonishing mobile performance for efficient workflow. In addition, its longer SID enables more convenient and comfortable operation for both operator and patient. PROSTAR's high voltage generator with short and sharp pulses ensures clear and high-resolution images under any circumstances. The high technology of the generator also contributes to the distinctive reduction of dose levels. With its high resolution CCD Camera, PROSTAR lucidly visualizes the anatomical structures and provides excellent images to make use of.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →