• Patented Parallel-Bar technology guarantees high fidelity signals • Multi-function design embeds Triaxial Accelerometry in each sensor • Patent Pending Motion Artifact Suppression • Selectable +/-1.5g or +/-6g range • 64 Ch. of Real-time Analog Output for Motion Capture integration • Guaranteed performance to 40m • 8 hours of operation in full transmission mode • 2-hour recharge time • 16-bit resolution • Compatible with EMGworks software • USB Connection to PC (laptop or desktop) • <500us inter-sensor latency • Real-time feedback of signal strength & battery status
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
| Patient electrode gel Consumable. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →