Datrend · Model VPAD-ES 2
Tests to NFPA 99, AAMIES1, IEC60601 and IEC62353 standards Field upgradeable by installation of optional Apps Builtin wireless communication enables transfer of data from remote sites to corporate CMMS systems Can be configured to retrieve test data from nonDatrend Instruments STANDARD Manual Electrical Safety Testing per IEC 62353, AS 3551, AAMI/ANSI ES-1 & IEC 60601 standards Hi-resolution Android tablet Graphical User Interface USB connection to measurement base; Bluetooth connection to base optional Bluetooth connectivity for transfer of files to and from local devices (PC, smartphone, other tablets, etc.) Extensive internal storage Unlimited user comments in test records Integrated ECG & Arrhythmia Simulator Internal test record storage Prints test result reports to Wifi or Bluetooth printers (printer not included) Increases quality, accuracy, and consistency
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
Send out for annual re-certification.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →