Covidien · Model Kangaroo Connect
Magnetic feeding set identification system to ensure a match between the pump’s user interface and feeding set type State of the art STOP (Safety Threshold Overflow Protection) valve automatically prevent free flow conditions, even when feeding set is unloaded from the pump Audible alarm to indicate errors or feeding set loading conditions Pump orientation-independent design eliminates need for drip chamber on feeding set Sensor technology detects both upstream and downstream flow conditions Continous feed and dose feed capability Auto-prime feature reduces the need for time-consuming namual priming Extended hold option View previous 72 hours of feeding history 17 languages ~24 hour battery l; ife at 125 mL/hr (using Power Save and Airplane Mode) Unique wireless technology allows for: Remote troubleshooting for user support Future software upgrades and new features Long term historical trending to better meet patient needs Quiet pump operation Compact, lightweight design Tabeltop, bed rail or IV pole mounting Simple, one-handed loading of pump cassette Pump is designed for cleaning under running water Rubberized casing for better grip Pole clamp can detach from pump without removing from IV pol.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The pump alarms and displays an error message / code and stops.
Root cause: A subsystem fault indexed in the service manual - motor / drive, a sensor, set-detection, or a board.
Symptoms: Repeated occlusion alarms, delivery stops, or an occlusion is missed.
Root cause: Kinked or clamped line, a closed roller clamp, a positional patient tube, pressure-sensor drift, or an improperly loaded set.
Symptoms: No or inaccurate feed delivery, set not detected, cassette / rotor error.
Root cause: Worn rotor / pump mechanism or a mis-loaded feeding set.
Symptoms: Delivered volume outside tolerance on the annual test, especially at low rates.
Root cause: Worn pumping mechanism / plunger drive.
Symptoms: Short run time, low-battery early after a full charge.
Root cause: Aged battery pack.
Symptoms: Set will not load, door will not latch, plunger grip poor.
Root cause: Worn door latch, plunger jaws, or anti-free-flow mechanism.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Pumping mechanism / rotor / plunger drive | Major service part | $$$ | Difficult |
| Pressure / air-detector sensor assembly | Major service part | $$ | Moderate |
| Door / latch / anti-free-flow assembly | Major service part | $$ | Moderate |
| Drive motor / gearbox | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.