CORPAK Medsystems · Model CORFLO Feeding Tubes
Patented ULTRA anti-clog outlet port significantly reduces the occurrence of clogging. The largest selection of adult, pediatric and neonatal feeding tubes to allow one-stop sourcing for all your feeding tubes hospital or system-wide. Patented TRAK feeding tubes: The ONLY feeding tube that can be used with the CORTRAK Enteral Access System. CORFLO Anti-IV prevents inadvertent feeding into an IV line. Compatible only with oral tip syringes for pediatric and neonatal use. The Ultimate in Patient Safety: All CORFLO feeding tubes are printed with centimeter marks for increased patient safety and intubation accuracy. The entire CORFLO polyurethane feeding tube line is color coded to correspond to varying lengths. Stylet lengths are matched to the CORFLO feeding tubes. Clinician Convenience and Patient Comfort: Flow-through stylets to flush, auscultate and aspirate during the insertion procedure. Water activated lubricant on all polyurethane feeding tubes for greater patient comfort during intubation and effortless stylet removal. 100% radiopaque for X-ray confirmation. Weighted tubes use multiple tungsten weights allowing for flexibility and greater comfort during intubation. "Y" ports on all CORFLO polyurethane feeding tubes minimize touch contamination and make flushing easy. CORPAK MedSystems' feeding tubes are the standard by which all other feeding tubes are measured!
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The pump alarms and displays an error message / code and stops.
Root cause: A subsystem fault indexed in the service manual - motor / drive, a sensor, set-detection, or a board.
Symptoms: Repeated occlusion alarms, delivery stops, or an occlusion is missed.
Root cause: Kinked or clamped line, a closed roller clamp, a positional patient tube, pressure-sensor drift, or an improperly loaded set.
Symptoms: No or inaccurate feed delivery, set not detected, cassette / rotor error.
Root cause: Worn rotor / pump mechanism or a mis-loaded feeding set.
Symptoms: Delivered volume outside tolerance on the annual test, especially at low rates.
Root cause: Worn pumping mechanism / plunger drive.
Symptoms: Short run time, low-battery early after a full charge.
Root cause: Aged battery pack.
Symptoms: Set will not load, door will not latch, plunger grip poor.
Root cause: Worn door latch, plunger jaws, or anti-free-flow mechanism.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Pumping mechanism / rotor / plunger drive | Major service part | $$$ | Difficult |
| Pressure / air-detector sensor assembly | Major service part | $$ | Moderate |
| Door / latch / anti-free-flow assembly | Major service part | $$ | Moderate |
| Drive motor / gearbox | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Firm is initiating voluntary correction of CORFLO PEG with ENFit. Barb connector (stem) of the adapter may break unexpectedly when exposed to stress.
The wrong size Twoomey adapter was packaged with the Jejunal tube.
Corpak is removing the Corflo 300 Enteral Pump from the market due to the possibility that with fluid ingress or other damage, the keypad may not function, and the possibility of motor mount failure.