Clinical Dynamics · Model EST-2
EST-2 Electrical Safety Tester The is designed for testing the electrical safety of any electrical device including medical equipment with patient leads. It can be used to verify manufacturer’s specifications, to periodically maintain equipment safety and performance, and to verify the condition of a product following production. The wide power input range allows use of the unit on 110 or 220 volt systems without modification. The power outlet can be replaced by the user to adapt to any available outlet. Universal adapter outlets are available. The EST-2 is lightweight and easy to use. It is portable and perfect for both field and bench top use. Measurements include Line Voltage, Device Current, Leakage Current, and Resistance. Normal and Reverse Polarity, Open Neutral or Open Ground conditions are easily simulated without the need for additional equipment or wiring. Leads leakage measurements may be made in all of the above conditions for 12 patient leads. The desired test function can be selected easily from the front buttons and the measurement value read directly from the large display. [b][i]As of May 1st, 2015, this product has been discontinued. [/i][/b]
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its scheduled factory / accredited calibration (at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, patient-lead adapters, or a sensor cable.
Symptoms: One parameter (leakage, insulation, ECG / SpO2 / IBP simulation, defib / pacer energy, ventilator flow / pressure, light / dose) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.