Cecil Instruments · Model ADEPT HPLC SYSTEM 6S
Automatic Binary Gradient - High Pressure Gradient Two Adept CE 4100 pumps each deliver at flow rates of 1.001 to 10mL/min and are connected to a dynamic mixer CE 4120. The dual wavelength detector CE 4200, is stacked above the pumps. The automatic sample injector CE 4800 which accommodates 50 samples completes the system, which is supplied with 8µL x 10mm flowcell and installation kit 4150 02 01. The very high performance of the detector, with exceptionally low drift, provides a very stable system for extended measurements. Full system control and data processing are provided by the PowerStream system manager and software.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, poor chromatographic peaks, baseline drift.
Root cause: Column / mobile-phase issue, detector lamp ageing, a pump / seal fault, or a reagent problem.
Symptoms: Pressure spikes or drops, unstable flow, retention-time drift.
Root cause: Worn piston seals or check valves, a blocked frit, or air in the pump head.
Symptoms: Missed injections, poor injection precision, vial-detection errors.
Root cause: Rotor-seal wear, a syringe / metering fault, or needle mis-alignment.
Symptoms: High noise, low signal, detector-error message.
Root cause: Lamp at end of life or a contaminated flow cell.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Pump piston seals / check valves | Frequent wear item | $$ | Moderate |
| Detector lamp | Frequent wear item | $$ | Moderate |
| Injector rotor seal | Frequent wear item | $$ | Moderate |
| Flow cell | Periodic replacement | $$$ | Moderate |
| Inlet frits / filters | Frequent wear item | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio