BPL Medical Technologies · Model E - Flo 7
10.1 inch Colour TFT Screen with display of Pressure-time, Flow-time & Volume-time waveforms and P-V, F-V, F-P Loops Standard Ventilation Modes of VCV, PCV, SIMV(V) + PS, SIMV(P) + PS, Manual & Standby Advanced proportional solenoid valve technology to realize accurate ventilation control Electronic flowmeters for O2, N20, Air with High accuracy and easy reading Closed – loop control for exact monitoring Comprehensive alarm system Compact and light weight body design for easy and safe maneuverability Yoke system (1xO2, 1xN2O; without Cylinders) Lithium battery: 120 Minutes of monitoring Heater of Absorber By-Pass of Absorber Optional: Vaporiser, SpO2Module, Mainstream CO2, Active AGSS System, Communication Interface, Autoclavable function of Absorber, Auxiliary Oxygen flow meter, Mainstream Gas Module for 5 kinds of Anesthetic Agent, AIR/O2 Driving for Ventilator with Auto Switching, Gas and Agent consumption calculation software Package.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The anesthesia is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.