Acoma Medical · Model PRO-NEXT
Injection Type VCV, PCV and PSV (Optional) ventilation mode are available. Electronic control PEEP Alarm off function Desflurane anesthesia is available. Flow sensor accuracy is improved. Tidal volume setting can be applied from 30 mL. Functional O2 flush button. Battery backup: 30 minutes Patient unit is equipped with O2 sensor and flow sensor. Space saving design. Injection type vaporizer: Accurate control digital vaporizer adjusts anesthesia concentration by 0.1%. Sevoflurane concentration is available from 0 to 8.0%. Isoflurane concentration is available from 0 to 6.0%. Anesthesia agent bottle can be directly attached to the main unit. Easy and safe handling. Digital flowmeters allows fresh gas flow to be adjusted with 10 mL increments. Backlight is equipped. Consumption of O2, N2O, and anesthesia agent Sevoflurane and Isoflurane can be monitored. Standard type Next generation functional anesthesia machine. VCV, PCV and PSV (Optional) ventilation mode are available. Electronic control PEEP Alarm off function Desflurane anesthesia is available. Flow sensor accuracy is improved. Tidal volume setting can be applied from 30 mL. Functional O2 flush button. Battery backup: 30 minutes Patient unit is equipped with O2 sensor and flow sensor. Space saving design. Vaporizer: 2 units.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The anesthesia is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio