Bowa Electronic GmbH · Model Arc Plus
With its argon plasma coagulation technology, the ARC PLUS is the ideal supplement to the ARC generator range. Argon-assisted spray coagulation can even work reliably with arcs in the extremely low power range of less than 10 Watts. As a result of their low coagulation depth, they only cause minimal necrosis of the tissue, which favours their use in areas at risk of perforation. Two ranges are available for the use of different argon accessories: Argon and Argon-Flex.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →