Bovie · Model Icon GP
• Easy to Use: - Touch-screen interface with high resolution TFT color display - no buttons or knobs. - Swivel bezel allows the screen to be viewed from almost any angle. - Intuitive graphical user interface allows easy setup and quick settings adjustments. - Physician Preference database provides a quick changeover between cases. Safety: - Bovie NEM is recognized amongst the safest technology available to reduce the risk of pad burns. - Increases patient safety by requiring the use of only split pads. - Common sense error messaging prevents misinterpretation and allows for quicker troubleshooting. - Laparoscopic Modes to help prevent capacitive coupling induced burns. Upgradeable: - Digitally controlled outputs and user interface means that new modes can be added so that your unit is never outdated. - Multiple communication ports (i.e. USB, RS 232 and Ethernet) allow the Icon GP to link up with other equipment in the OR. - New accessory connector for future devices. Clinical Benefits: - Variety of modes allows for tailored settings for many surgical applications. - Bovie FDFS Technology calculates the impedance, 5000 times per second by sampling the current and voltage 5,000,000 times per second.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →