BK Medical · Model Falcon 2101 EXL
Frequency range of 1-20 MHz provides the highest resolution in its class Four transducer connectors (three array and one mechanical) B-K Medical’s patented continuous uniform focusing technology ensures optimal resolution at all image depths Compact and mobile, so it can be used wherever and whenever you need it Ergonomic, with height-adjustable keyboard and monitor and logically grouped controls Full 15″ flicker-free monitor provides optimum viewing Optional fully integrated 3-D package, including tracked pullback support for relevant transducers Simultaneous split screen feature lets you display two active ultrasound images on the monitor at the same time Convenient storage space on the unit itself, with a compartment under the keyboard for accessories Upgradability ensures you of long-term investment security
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dropout, dead elements, image banding.
Root cause: Element delamination or cable damage from repeated use.
Symptoms: Intermittent image loss, connector-wiggle artifact.
Root cause: Repeated flexing and connector strain.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Dim image, color shift, dead pixels.
Root cause: Backlight or LCD panel aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Handle with care; most-replaced probe assembly.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Ultrasound transducer / probe Handle with care; most-replaced probe assembly. | Periodic replacement | $$$$ | Moderate |
| Transducer cable assembly | Periodic replacement | $$ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Display panel | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.