Biotec Fischer · Model Phero-Sub 1010-E
Electrophoresis System With gel tray options of 10 x 7cm and 10 x 10cm, the multiSUB Midi has been designed for routine horizontal gel electrophoresis. Extending only the width of this unit allows more samples to be resolved per gel than the PHERO-sub 1010-E without a significant increase in buffer or gel volumes. A maximum of 100 samples per gel can be resolved making this unit ideal for those routinely checking medium numbers of samples over short to medium gel run lengths.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Run will not start, "no load" or "leak" fault, voltage / current will not hold the setpoint.
Root cause: Power-supply output fault, a bad tank / lead connection, buffer-conductivity issue, or a cracked electrode.
Symptoms: Leaks at the tank, warped lid will not seat, broken platinum electrode wire.
Root cause: Cracked tank / lid or a broken electrode.
Symptoms: Dark or uneven images, transilluminator / LED not working, camera not detected.
Root cause: Transilluminator LEDs / tubes, the camera, or the imaging software.
Symptoms: Runs overheat, poor resolution, temperature alarm.
Root cause: Cooling fan / Peltier or a coolant fault.
Symptoms: Runs will not program, images / data will not save or analyse.
Root cause: PC or software / license.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Power-supply output board | Major service part | $$ | Moderate |
| Tank / lid / electrode set | Periodic replacement | $$ | Fairly easy |
| Transilluminator LEDs / tubes (imagers) | Periodic replacement | $$ | Fairly easy |
| Camera module (imagers) | Major service part | $$$ | Moderate |
| Cooling fan / Peltier | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.