Bioneer · Model ExiSpin
• Fully Automated Spin-Mix-Spin Technology - Each time and strength of centrifugation/mixing can be programmable. The repetition numbers of spin-mix-spin step can be set (1-999 cycles). After input, it is operated by single button automatically as followings. - 1st spin: Spin down samples to a bottom of tube Mixing samples - 2nd spin: Spin down mixed samples to a bottom of tube from wall and cover • Convenience and High Reproducibility - It provides reproducible results using protocols optimized to samples by preventing the possibilities of experimental errors. Four 8-strips tubes can be handled simultaneously, which enable 32 PCR/QPCR mixture tubes ready to run at once. Twelve 1.5 ml tubes can be loaded for simultaneous cell lysis and subsequent centrifuge-down. The programmed speed and time quarantine the reproducibility of each application. • Economical Efficiency - ExiSpinTM has the centrifuge and vortex function. You can save not only your time but also the budget by purchasing one instead of two separate equipments. 12 X 1.5 ml rotor and 4 X 8-strip rotor are easily changed and both rotors are included in the basic system.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →