Biolitec · Model Ceralas G Series
• Ceralas G5 for Dermatology and ENT 5-Watt 532nm Diode-Pumped Nd:YAG Laser - With superior absorption in hemoglobin and an adjustable pulse length, the G5 provides extremely dependable, precise, and gentle treatments for vascular and pigmented lesions. The Ceralas G5 has several useful applications in Dermatology, Plastic Surgery, and ENT – including treatments for vascular and pigmented lesions such as telangiectasia, hemangiomas, and fibromas. • Ceralas G3 for Ophthalmology 3-Watt 532nm Diode-Pumped Nd:YAG Laser - The Ceralas G3's excellent absorption in hemoglobin and it's adjustable pulse length allows it to provide extremely dependable, precise, and gentle treatments for Ophthalmological photocoagulation. The G3 is ideal for the photocoagulation of ocular tissue, ablation of the tissue of the iris and trabeculum, photocoagulation of retinal tissue, ocular tissue, and vascular and pigmented skin lesions.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dim illumination, lamp error.
Root cause: Xenon/LED aging.
Symptoms: No phaco power, error.
Root cause: Tip or handpiece wear.
Symptoms: Unstable anterior chamber.
Root cause: Peristaltic pump wear.
Symptoms: Blurry/offset image.
Root cause: Camera calibration drift.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
High-value, track usage.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Illumination lamp / LED | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable. | Frequent wear item | $ | Easy |
| Imaging camera module | Periodic replacement | $$$ | Difficult |
| Phaco handpiece / tip High-value, track usage. | Periodic replacement | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →