Biocare · Model iE 15
Compact and elegant notebook design 12.1-inch high resolution TFT LCD with touch screen, easy to view Full alphanumeric keyboard with shortcut keys, efficient in operation Broad frequency response 0.05~250Hz for weaker signal recognition and capture, more suitable for pediatrics 15-lead ECG for adults and pediatrics, Vector cardiograph, 12-lead ECG, all-in-one VCG and vector loop for more advantages in diagnosis of the right atrium & ventricular hypertrophy, conduction block, myocardial infarction and so on New generation acquisition module, more quickly, stable and accurate in ECG signal process New filtering technology effectively guarantees waveforms against AC interference, wandering and overlapping Massive local storage for up to 1500 files Exclusive Biocare CardioPro ECG analysis program Apply the latest Minnesota code 7 working modes catering for clinical demands 18 report formats on printing 3 ways of file storage: local memory, SD card, USB flash disk ECG management software (optional)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →