Beckman Coulter · Model Unicel Dxi 800
Standardized design of reagent packs Compatibility across immunoassay systems Minimal reagent preparation or reagent management required Bar-coded, liquid, ready-to-use reagents Onboard capacity of 50 refrigerated reagent packs enhance flexibility - configure the system menu to match testing requirements A broad menu across a wide variety of disease states enables your laboratory to consolidate workstations Simplified operation improves productivity Load reagents and all consumables ‘on-the-fly’, without using the console computer or pausing the instrument, minimizing intervention Easy-to-follow pictogram and indicator lights show which supplies need replenishment Large volume supplies maximize walkaway capacity Streamlined sample handling Load capacity of 120 samples at once; continuous loading capability Racks are compatible with SYNCHRON LX systems, decreasing sample handling across multiple systems Racks can be loaded directly from the centrifuge, reducing manual processes Routine sample loading can be interrupted to load STAT samples quickly “Point-in-space” pipetting technology aligned with NCCLS guidelines allows integration with laboratory automation systems Releases primary tube in less than five minutes for testing in other areas of the lab On-board aliquot capability Automatically creates aliquots based on the volume of requested tests plus any additional volume that may be required for user-defined reflex or re-run test scenarios System stores aliquots for up to three hours in a patented, refrigerated low-evaporation compartment Simplifies inventory management - utilize same type of vessel for aliquots and reactions Proven chemiluminescent detection delivers excellent precision and sensitivity with a broad dynamic range System supports multiple assay protocols to ensure peak assay performance Magnetic particle separation with chemiluminescent detection delivers exceptional clinical performance Rapid assay kinetics improve TAT Innovative system delivers powerful efficiency Intuitive operator interface, with touch screen capability, maximizes efficiency Auto-matched pipettors work in parallel to deliver sample and reagent into the reaction vessels – and achieves a peak throughput of 400 tests per hour
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.