BD · Model Pyxis MedStation ES System
Simplified caregiving - Efficient, patient-centric clinical workflows guide nurses to medication and patient information in one place. Enhanced formulary integration and management - PIS integration can result in one centrally manageable system formulary, supporting standardization, with site-specific adjustability. Enhanced safety - New safety enhancements help prevent potentially harmful medication errors and adverse drug events. Reduced risk - The system sustains uptime while minimizing disruptions, delays and risk of medication error. Streamlined user management - Integration with Active Directory simplifies system user management.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Commanded drawer does not release or jams partway.
Root cause: Drawer solenoid or motor, a jammed rail, or an over-filled pocket.
Symptoms: No response or offset touches.
Root cause: Touchscreen controller or calibration fault.
Symptoms: Cannot log in, station offline, formulary not syncing.
Root cause: Network path, the station NIC, the ES server, or the Active Directory link.
Symptoms: Station does not ride through a brief outage.
Root cause: Aged internal UPS battery.
Symptoms: Scanner will not read or no printed record.
Root cause: Scanner window/cable or printer paper/head.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drawer solenoid / drive motor | Major service part | $$ | Moderate |
| CUBIE pockets | Major service part | $$ | Fairly easy |
| Touchscreen assembly | Major service part | $$$ | Moderate |
| UPS battery | Periodic replacement | $$ | Fairly easy |
| Network interface / barcode scanner | Major service part | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.