BC Group · Model ULT-2010
Tests the Upper & Lower Leakage Current Limits per Ultrasound Mfr. Specifications. Range 0.5 to 500 uA - Designed to Meet Mfr. Transducer Specifications. Large Graphic Display w/Backlighting Allows Easy Selection of Options & Setup of Parameters. User-Selectable Challenge (Test) Voltage (90 to 275 VAC) & Frequency (50 or 60 HZ). User-Selectable Test Limits. Programmable Test Limits Based on Ultrasound Transducer Mfr. & Type. 1% F.S. Range Accuracy. Auto Ranging for Enhanced Accuracy Over Entire Range. Single Button Press for Full System Test. Selectable Pass/Fail or Numerical Test Results. User-Selectable Display Options. Programmable Backlight Timer. Flash Programmable, Field Upgradeable. Compatible with Dale Technology® & Fluke Biomedical® Adapters & Probes. RS232 Interface. PC Utility Software for Configuration. Setup & Remote Control. Test Results Printable with Optional Printer. On-Board Clock & Calendar Function for Date/Time Stamp of Test Records. On-Board Storage for up to 99 Test Records. Audio-Visual Test Status Notification.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its scheduled factory / accredited calibration (at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, patient-lead adapters, or a sensor cable.
Symptoms: One parameter (leakage, insulation, ECG / SpO2 / IBP simulation, defib / pacer energy, ventilator flow / pressure, light / dose) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio