Bard · Model Site~Rite 6
Large 12.1” screen 4 image options for a sharper or smoother image Vessel wall sharpening Vascular access image depths Superficial 1.5 cm image depth for shallow imaging Deep 6 cm image depth for deeper needle guidance including bariatric patients Ability to input patient information Intuitive and easy-to-use control buttons 60-minute internal battery Vascular access probe Solid state vascular access probe Buttons located on the probe allow control, including printing, from within the sterile field Integrated carrying handle for portability Locking drawer for sharps and medicines Flat workspace for flexibility during bedside vascular access device placement Vertical file for medical files and patient charts Large storage bins for transport of needle guide supplies used in vascular access device placement 2.5-hour external battery and A/C adapter Large wheels for negotiating elevator transitions and other obstacles
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.