Arjo · Model Maxi Move
POWERED DPS Powered dynamic positioning system (PDPS) minimises manual handling and improves precision when positioning the patient. COMBI ATTACHMENT The Combi attachment makes it smooth and easy to change between different spreader bars and stretcher frames. DUAL CONTROLS Dual controls on the mast and the hand control. Using the hand control gives the caregiver the opportunity to move and stay close to the patient and maintain good eye contact throughout the lift and transfer process. TELESCOPIC VERTICAL MAST Vertical mast provides stability while the patient is lifted. CASTOR SIZE Three castor sizes available: standard, low and extra-low to facilitate access under low beds and trolleys. SCALE (OPTION) Optional integrated scale supports an efficient weighing routine.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Short runtime, low-battery alarm.
Root cause: Aged battery.
Symptoms: Intermittent signal/power.
Root cause: Repeated flexing.
Symptoms: Loose device, vibration damage.
Root cause: Docking latch wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical for transport; spares mandatory.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set | Periodic replacement | $$ | Easy |
| Rechargeable battery pack Critical for transport; spares mandatory. | Frequent wear item | $$$ | Fairly easy |
| Docking cradle / latch | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
The battery pack NDA0200-20, lot 070826D, sold with the Maxi Move patient lift or as replacement parts, has a defective connector that could lead to the inability of the battery pack to recharge and/or short circuit, resulting in smoke emission.
There is the potential for unintended dislocation of the Lock and Load hanger assembly (Combi Hanger) from the t-bar attached to the lifter jib of the Maxi Move patient lift.
The armrests of the lift chair may push up, allowing the patient to slip down and out of the seat. The resultant fall could result in serious or fatal patient injuries.
The hanger bar assembly may detach from the Maxi Move lifters with scale, due to an incorrect torque setting on the two bolts holding the scale in place.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →