High Friction Solution Dual Controls Adjustable leg chassis Optional scale.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Lift / lower / (Sara/Sabina) seat or leg functions do not respond to the hand control.
Root cause: Discharged or mis-inserted battery, an active emergency stop, an obstruction or overload, or a faulty hand control / cable.
Symptoms: One movement will not run, runs one direction only, noisy or slow.
Root cause: Worn linear actuator or a limit-switch fault.
Symptoms: Short run time, frequent low-battery, unit dies mid-transfer.
Root cause: Aged battery pack or a charger / charging-contact fault.
Symptoms: Sling loops fraying, sling bar hook worn, seat belt frayed, attachment not secure.
Root cause: Wear - inspect before every use and retire per Hillrom / Arjo guidance.
Symptoms: Hard to move, a caster seized, brake will not hold.
Root cause: Debris or a worn caster / brake.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Inspect before every use; retire per Hillrom / Arjo guidance.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Easy |
| Hand control | Periodic replacement | $$ | Easy |
| Linear actuator | Major service part | $$$ | Difficult |
| Caster set | Periodic replacement | $ | Fairly easy |
| Slings / seat belts / lifting accessories Inspect before every use; retire per Hillrom / Arjo guidance. | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
If the spring pin is not properly reinstalled after maintenance, the pivot bolt could unscrew by itself within a limited period of time, resulting in a hanger bar detachment.
The pivot bolt that attaches the hanger bar to the scale of the patient lift can break, resulting in the hanger bar falling.