Alsa · Model Excell 200
Diathermy units and argon gas enhanced diathermy units for major surgery For every operational need. The equipments of the series EXCELL MCDSe are electrosurgical units for major surgery, suitable for all operations where the monopolar and the bipolar techniques are used, as well as the monopolar mode with the Argon gas flow. The units are available in 5 different models. The models EXCELL 400 MCDSe, EXCELL 350 MCDSe, EXCELL 250 MCDSe, and EXCELL 200 MCDSe are indicated for electrosurgery. By the contrary, the model EXCELL 400/A MCDSe is suitable both for electrosurgery and electrosurgery with Argon gas. It is equipped with all the necessary functions for this type of application, and so it is easier to use.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.