Aloka · Model SSD-3500
The high-performance, ALOKA ProSound SSD-3500 utilizes advanced ProSound technologies Fully digital beam former A wide dynamic range, 12-bit A/D converter Multi beam processing The SSD-3500 also helps you achieve more efficient examinations. Its ergonomic, user-friendly design enables you to customize the system according to your specific application needs [u]A Better Diagnostic Tool[/u] High performance digital imaging capabilities An easy-to-use ultrasound system Aloka’s SSD-3500 combines the latest in digital processing technology with high resolution transducer engineering to deliver a powerful ultrasound system for examining the musculoskeletal system of the body. SSD-3500 is the perfect system to detect problems with muscles, tendons, joints, and soft tissue. Diagnosing tendon tears (e.g., tears of the rotator cuff in the shoulder) Diagnosing bleeding or other fluid collections within the muscles, bursae, and other joints Easily guiding therapeutic needles Identifying the degree of vascularity associated with inflammatory processes And because ultrasound is a dynamic imaging modality, impingements and tears are easily visualized on the monitor. [u]Digital Processing/PixelFocus[/u] A 100% digital processing technique that allows the SSD-3500 to focus down to the pixel level to provide for very high quality spatial resolution for improved visualization of clinical detail. [u]High Performance12-bit A/D Converter[/u] Achieve high-quality images with the broad dynamic range and high contrast resolution with our 12-bit A/D converter. [u]Digital Storage[/u] The SSD-3500 supports data storage in multiple formats including DICOM, TIFF, JPG, and BMP using its iDMS (Intelligent Data Management System) software. [u]Color Doppler[/u] Wide dynamic range ColorFlow, PowerFlow, and Tissue Doppler Imaging provide outstanding analysis of blood flow morphology. [u]Dual Dynamic Display (DDD)[/u] Simultaneously display two B-mode images (with and without color flow) to easily show the relationship between the morphological information and the blood flow of the region of interest. [u]Tissue Harmonic Echo (THE)[/u] The SSD-3500 utilizes second harmonics, which include much less side lobe artifact and noise, and provides improved tissue differentiation with increased contrast resolution. This also helps imaging of difficult-to-exam patients such as the aged and the obese. [u]Small Footprint[/u] In a crowded office setting, space if often hard to find. Surprisingly, the SSD-3500 takes up little space. And with its adjustable monitor and keyboard, the SSD-3500 is easy to use and comfortable to operate. Digital Proccessing/Pixel Focus Color Doppler Dual Dynamic Display Tissue Harmonic Echo Small Footprint Multibeam Processing.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy, low-contrast or non-uniform image, missing sector, drop-out that follows the system not the probe.
Root cause: Front-end / beamformer board fault, a probe-port (connector) board fault, or a system-board fault.
Symptoms: A probe works on one port but not another, or is not detected at all.
Root cause: Worn probe-port connector or a scan-connector board fault.
Symptoms: Dead system, hangs at boot, or powers off under load.
Root cause: Power supply / DC converter, the system battery, or a system-board fault.
Symptoms: Unresponsive TGC sliders or keys, distorted or blank display.
Root cause: Control-panel board, touchscreen, or the monitor.
Symptoms: Thermal-shutdown warning, fan roar, hot exhaust.
Root cause: Failed or dust-clogged cooling fan or blocked air path.
Symptoms: Studies will not send to PACS, images will not archive, worklist empty.
Root cause: Network configuration or a storage-drive fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Front-end / beamformer board | Major service part | $$$$ | Difficult |
| Probe-port / scan-connector board | Major service part | $$$ | Difficult |
| Power supply / DC converter | Major service part | $$$ | Difficult |
| Control-panel / touchscreen assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
| System hard drive | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.