Aloka · Model ProSound SSD-5000
Digital Pure Beam Imaging technology, including a Digital Beam Former and a high-performance 12-bit A/D converter, greatly improves the dynamic range of an image in both the near field and far field, enabling the physician to visualize deeper organs that may have previously been difficult to see. Compatibility with the Hemispheric Sound Technology probes, providing significant focal improvement in both the lateral and elevation planes Sensitive Color and Power Doppler Imaging allows for the detection and interpretation of blood flow conditions, making the visualization of even minute vessels within and around the GI tract more visible Quad Frequency Imaging allows the user to switch the Olympus GF-UC140P/UCT140-AL5 among 4 frequencies for higher image optimization Dual Dynamic Display (DDD) makes it possible to display, in real-time, a simultaneous split screen of both the B-mode (grayscale or ultrasound) image and color Doppler Data Management System stores, maintains and exports images, produced by Digital Pure Beam Imaging technology without any analog conversion, thereby eliminating image degradation PixelFocus provides precise spatial resolution Image Processing Select provides a range of pre-set functions for all modes using easy rotary control Color touch control panel State-of-the-art design provides increased mobility.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy, low-contrast or non-uniform image, missing sector, drop-out that follows the system not the probe.
Root cause: Front-end / beamformer board fault, a probe-port (connector) board fault, or a system-board fault.
Symptoms: A probe works on one port but not another, or is not detected at all.
Root cause: Worn probe-port connector or a scan-connector board fault.
Symptoms: Dead system, hangs at boot, or powers off under load.
Root cause: Power supply / DC converter, the system battery, or a system-board fault.
Symptoms: Unresponsive TGC sliders or keys, distorted or blank display.
Root cause: Control-panel board, touchscreen, or the monitor.
Symptoms: Thermal-shutdown warning, fan roar, hot exhaust.
Root cause: Failed or dust-clogged cooling fan or blocked air path.
Symptoms: Studies will not send to PACS, images will not archive, worklist empty.
Root cause: Network configuration or a storage-drive fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Front-end / beamformer board | Major service part | $$$$ | Difficult |
| Probe-port / scan-connector board | Major service part | $$$ | Difficult |
| Power supply / DC converter | Major service part | $$$ | Difficult |
| Control-panel / touchscreen assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
| System hard drive | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.