Digital Display for Line Input Voltage, Supporting user to operate at 220V for accurate results. Auto Programmable unit. Indication of Body part on each, With press of a button the kVp, mA and mAs is automatically selected. LCD Display for kvp, mA and mAs. With Each Body part, Bucky is automatically selected where ever required. 24 Auto Programmable buttons for various Body parts And 12 Additional APR buttons for user to store additional values. Manual selection of kVp, mA and mAs for Increase/Decrease. All APR buttons can be reprogrammed at customer's Place as per requirement. Each kVp step of 2kVp, thereby giving better Radiographic results. Microprocessor Based Overload Protection for 100% safety. Microprocessor Based Electronic Exposure Control for Accurate exposure to the level of Micro Secs. Automatic Overload protection with visual & audible indication for longer life of the Tube. Automatic cutoff for High Input Voltage. mAs... Each Step of 2 mAs, thereby giving much higher Timer combinations. Count of Number of Exposures possible.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.