Abbott · Model NT2000IX
Independent timers ensure you can deliver a complete treatment to each targeted nerve by giving you the ability to independently monitor lesion times for each channel. Responsive stagger start enables you to quickly identify under-anesthetized nerves. Unique temperature control algorithms are designed to intelligently regulate power to each electrode. Four dedicated RF amplifiers enable continuous delivery of energy to each treatment site. Manual stimulation and radiofrequency control knobs enable you to make fine adjustments. Settings, patient profiles and site labels can be preloaded to minimize confusion during procedures. 5-inch touch screen with a simple, intuitive interface makes it easy for you to see procedural data to minimize errors. Dedicated software algorithms support specialty procedures. Bluetooth wireless communication for printing and wireless mouse compatibility provides versatility in both document management and user interface control.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Certain NT2000iX RF generators were serviced using a tool that was subsequently found to be out of tolerance and therefore may not have provided accurate results for potential capacitance failure.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.