A dec · Model 500 Stool
Tilt Seat. Distributes weight from seat to feet allowing proper circulation. Contoured Backrest. Cradles the spine, while encouraging blood flow. Contoured backrest is standard on the A-dec 500 doctor’s stool and optional on the A-dec 500 assistant’s stool. Whisper Quiet Casters. New design provides smooth, ultra-quiet movement on both carpet and hard flooring. Adjustment Controls. Labeled paddles are easy to access for quick adjustments and easy cleaning. Backrest Height Control. A push button makes access and one-handed adjustment easy. Upholstery. Minimal seams make clean up easy. Two Cylinder Heights (A-dec 500 doctor’s stool). Measure from hips to the feet. Above 34" - choose tall cylinder. Under 34" - choose short cylinder. Height-Adjustable Foot Ring (A-dec 500 assistant’s stool). Helps practitioner maintain correct posture.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Low RPM, noise, poor cut.
Root cause: Bearing/turbine wear.
Symptoms: Low air pressure, moisture.
Root cause: Worn compressor / dryer.
Symptoms: No/erratic activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Weak cure, low intensity.
Root cause: LED aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Most-replaced; track autoclave cycles.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Handpiece turbine / cartridge Most-replaced; track autoclave cycles. | Frequent wear item | $$$ | Moderate |
| Air compressor & dryer | Periodic replacement | $$$ | Difficult |
| Foot pedal | Periodic replacement | $$ | Fairly easy |
| Curing light LED head | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →