Zimmer · Model ATS 1200
Safety: Battery back-up, visual and audio alarms, positive locking connectors, and other proprietary features help ensure patient safety. Cuff lockout feature keeps the cuff inflated even if the unit is turned off. Reliability: Advanced microprocessor technology includes self-diagnostic tests and continuous monitoring for consistently dependable performance. Convenience: Fast inflation and deflation save time for busy operating room personnel. Ergonomic contours facilitate handling and operation for positive, confident control. High Quality Inflation: The A.T.S. 1200 addresses important concerns in medical tourniquet system design, providing the features that healthcare facilities demand for safety, reliability, and convenience. Patient Safety: Dual cuffs provide precise, independent monitoring and performance for bilateral or bier block procedures. Accurate pressure monitoring for patient safety and confidence. Positive-locking connectors supply safe, leak-free inflation. Angled ports keep connectors clear of the surgical site. Visual and audio alarms readily detect pressure variations. Cuff Features: Low-profile cuffs stay in place without discomfort. Select reusable cuffs or disposable sterile cuffs to eliminate cross-contamination. Cuff sleeves help reduce wrinkles, pinching, and shearing of soft tissue. Color-coded cuffs from 8 - 42" accommodate virtually all patients and limbs. User Friendly: Large LED display is adjustable and easy to read, even from a distance. Simple setup includes user-defined default pressure and time settings. Lightweight, portable unit can be mounted on an I.V. pole or placed on a table. 45-minute battery backup to help ensure continuous power. The A.T.S. Family: The A.T.S. family of Automatic Tourniquet Systems is designed to meet the specific demands of a variety of healthcare facilities and orthopedic and clinical applications. Zimmer tourniquet cuffs are a leader in the industry.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Main or second cuff does not pressurise on command.
Root cause: Membrane panel not seated, pump not plugged in, a stuck-open deflate valve, or a valve-driver / harness fault.
Symptoms: Cuff stays pressurised when deflation is commanded.
Root cause: Deflate valve stuck shut, or a valve-driver / harness fault.
Symptoms: Displayed pressure disagrees with a reference, self-check on power-up fails.
Root cause: Pressure transducer drift or a control-board calibration fault.
Symptoms: System repeatedly tops up the cuff, leak alarm, set pressure not held.
Root cause: Cuff bladder or hose leak, or a loose positive-locking connector.
Symptoms: Battery indicator lit or flashing during normal use, unit dies on transport.
Root cause: Aged backup battery or a charger fault (battery is for power-loss / transport only).
Symptoms: Unit fails at first use or mid-procedure.
Root cause: Subject of a Zimmer A.T.S. 3000 voluntary removal for out-of-box and intra-operative failures - check the unit's serial against the recall notice.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Recalibrate after replacement.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Air pump | Major service part | $$$ | Difficult |
| Inflate / deflate valve assembly | Major service part | $$ | Difficult |
| Pressure transducer Recalibrate after replacement. | Major service part | $$ | Moderate |
| Membrane panel / keypad | Major service part | $$ | Moderate |
| Backup battery | Periodic replacement | $$ | Fairly easy |
| Tourniquet cuff and hose | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Synced live from the FDA openFDA API.
Zimmer Biomet is recalling the Altius M-INI OCT Posterior Spinal Fixation System because the driver is unable to mate with the screw head tulip.
Zimmer is conducting a voluntary removal of some Zimmer A.T.S. 3000 tourniquets after receiving complaints of both out-of-box failures and failures during surgical procedures on some of the affected units. During failure the unit will alarm, lock into a non-operational mode, and the display screen will go blank. Based on investigation, this problem appears to be due to a counterfeit chip on the
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio