ZEISS · Model Opmi Visu 200
The X-Y coupling allows fine, motorized positioning of the surgical mi- croscope in a horizontal plane. The range of travel is 40 mm x 40 mm. The speed of travel can be set on the display field of the suspension system. Support arm for the surgical microscope The support arm incorporates a tilt device. This allows the viewing direction of the surgical microscope to be adapted to the requirements of the surgical field. Using the knob for fine tilt, you can position the surgical microscope in a range from +180° to -180° (+ in the direction of the surgeon and - in the opposite direction). The +90° setting is ideal for surgery on patients in a seated position or lying on their side. The apochromatic optics of the main microscope provide superb optical quality. The microscope image displays optimum contrast and excellent detail recognition along with a large depth of field. The bright microscope image is a particular benefit in vitreoretinal surgery.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →