ZEISS · Model LSM 780
32-channel GaAsP detector with a typical quantum efficiency of 45% – a significant improvement on the 25% typically achieved by classic PMT detectors Potential for photon counting on GaAsP and the new side PMT With lasers from 355 nm true UV to 660 nm far red, any dye will be excited optimally Simple adaptation to changing acquisition strategies via the ZEN software’s Smart Setup Improved ZEN software with modules for e.g. correlative microscopy, deconvolution and time lapse Improved dynamics for better visualization of weak signals Active cooling together with oversampling and photon counting modes deliver improved signal-to-noise ratio.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: One excitation line dim or absent, low signal on affected channels.
Root cause: Laser module (Ar, DPSS, HeNe or diode) at end of life or a laser-shutter / AOTF fault.
Symptoms: Dark or noisy image on the 32-channel GaAsP array or a side PMT, cooling alarm.
Root cause: Detector element degradation or a Peltier cooling fault.
Symptoms: Image distortion, tearing, scan errors, no image.
Root cause: Galvanometer scan-mirror or scan-control fault.
Symptoms: Z-focus drifts during time-lapse, stage will not move, definite-focus errors.
Root cause: Motorised focus drive or XY stage fault.
Symptoms: ZEN loses connection to the microscope or a component.
Root cause: Controller, firmware, or cabling.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
OEM service; laser-safety interlocks and alignment required.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Laser module (per line) OEM service; laser-safety interlocks and alignment required. | Periodic replacement | $$$$ | Expert-level |
| GaAsP detector array / cooling module | Major service part | $$$$ | Expert-level |
| Galvo scanner assembly | Major service part | $$$$ | Expert-level |
| Motorised focus drive | Major service part | $$$ | Difficult |
| Microscope controller board | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.