Varian Medical Systems · Model Gamma Medplus iX afterloader
24 channel or 3 channel system (The 3 channel system has the option of being field upgradeable to 24 channels.). High dose rate (HDR) and pulse dose rate (PDR) options. Unique design ultra-flexible solid core source cable. Fixed treatment length safety feature. Adjustable height. Multiple safety & backup features (e.g., on-board radiation detector and emergency retract system).
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Source will not advance, retract, or dwell at the correct position; positioning-error interlock; source retract on fault.
Root cause: Drive cable / motor wear, an obstructed or kinked transfer tube / applicator, or an indexer / channel fault.
Symptoms: Check (dummy) cable run fails, position verification does not match the plan.
Root cause: Check-source cable wear or an optical position-sensor fault.
Symptoms: Treatment aborts, source auto-retracts to the safe, alarms.
Root cause: Door interlock, timeout, power loss, or a detected drive fault - the fail-safe design retracts the source.
Symptoms: Area radiation monitor fault or disagreement.
Root cause: Area monitor detector or its calibration.
Symptoms: Console will not connect to the afterloader, plan will not transfer.
Root cause: Network / cable fault or a software fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Wear item; replace on the manufacturer's cycle count.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Source drive cable Wear item; replace on the manufacturer's cycle count. | Periodic replacement | $$$ | Difficult |
| Check (dummy) source cable | Periodic replacement | $$$ | Difficult |
| Transfer tubes / applicators | Periodic replacement | $$ | Fairly easy |
| Indexer / channel assembly | Major service part | $$$$ | Expert-level |
| Area radiation monitor | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Synced live from the FDA openFDA API.
A defective treatment applicator in a cancer therapy medical device may become separated potentially causing patient injury.
Manufacturer of brachytherapy instrument issued a Customer Technical Bulletin to clarify instructions for use of the radiation treatment medical device by healthcare practitioners.