Varian Medical Systems · Model Clinac 21EX/23EX
Two selectable photon beam energies Selectable dose rate up to 600MU/min Choice of electron energies to meet clinical needs, with electron applicators included Tight isocenter alignment of the gantry, couch, collimator, and imagers Reproducible, stable, and accurate machine positioning Exact couch for accurate reproducible patient positioning Modes for special clinical procedures, e.g. high dose total skin electron mode and total body X-ray mode Enhanced dynamic wedge saves time and the need to reenter the treatment room Auto field sequencing Dynamic procedure modes for photon arcs SmartConnect remote access technology provides access to Varian customer support expert assistance and online remote analysis.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Beam-on faults, dose-rate low or unstable, RF/HV or arc interlocks.
Root cause: Klystron / magnetron or thyratron at end of life, HV supply, or waveguide arcing / SF6 pressure loss.
Symptoms: Leaf stuck or out of position, delivery interlock, QA fluence errors.
Root cause: Millennium MLC leaf motor, leaf-guide wear, or a leaf position-readout fault.
Symptoms: Rotation, field-size or couch position error, position interlock.
Root cause: Drive motor, encoder, or brake.
Symptoms: kV or MV imaging degraded, poor image for setup, imaging-arm deploy errors.
Root cause: kV X-ray tube, amorphous-silicon panel, or the imaging-arm (Exact arm) drive.
Symptoms: Output constancy checks trend out, symmetry/flatness off, chamber interlock.
Root cause: Monitor ion-chamber aging or a dose-servo fault.
Symptoms: Over-temperature interlocks, dose-rate instability, coolant-flow alarm.
Root cause: Chiller pump, heat-exchanger fouling, or low coolant.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
OEM service; dosimetry re-commissioning required.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Klystron / magnetron OEM service; dosimetry re-commissioning required. | Periodic replacement | $$$$ | Expert-level |
| Thyratron | Periodic replacement | $$$$ | Expert-level |
| MLC leaf motor / drive assembly | Major service part | $$$$ | Expert-level |
| kV X-ray tube / a-Si imaging panel | Major service part | $$$$ | Expert-level |
| Monitor ion chamber | Major service part | $$$$ | Expert-level |
| Chiller pump / heat exchanger | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.