Thermo Scientific · Model Jouan KR4i
• Powerful brushless motor: Designed for continuous processing. • Blood Banking: 12 x Quin/Quad/Triple bags (buckets 2,000 ml), 8 x Quin/Quad bags with in-line Filter (patented liner, buckets 2,160 ml) or 6 x Quad/Triple bags. • Processing: 4 x 1,600 ml, 6 x 1000 ml. • Pathology and Research: Accepts up to 504 samples and all types of sample container. • Analyzer Sample Preparation: Accepts huge quantities of racks from analyzers of many brands for RIA, Hematology, Biochemistry. • Large choice of accessories: Offers three swing-out rotors, a wide selection of accessories and an unparalleled microplate capacity providing the ablity to process up to 48 standard microplates or 12 to 18 deepwell microplates in a single run. • Intuitive controls: VIDEOsetTM graphic control system with pictures and messages. • Careful sample handling: Liners enable blood bags to be inserted and removed without force. • High precision: Microprocessor control of all parameters. • Lifetime reproducibility: Guaranteed run to run by automatic High Reproducibility Factor (integral). Ideal for platelet production. • True RCF: Using programmed radius allowing for use of adaptors. • Ideal for process development: 24 program memory. • Accurate temperature control: Patented temperature sensor and software independent of the bowl for better sample temperature control. • Convenient: Can run without rotor lid for instant access to samples. • Maintenance-free motor: Quiet, brushless induction motor, designed and manufactured by Thermo. • Absolute safety: Sealed buckets and microplate carriers certified to IEC 1010-2-020 for biocontainment by C.A.M.R.* Porton Down. Imbalance detection & shutdown, guard barrier, dual lid interlock, current and temperature limitation.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.