Tenacore Holdings · Model Continuous-Full Suction Regulator
Analog 3 Mode VeeVo suction regulators are compact, easy-to-use and include many unique features. Each unit includes soft Side Grips™ that provide users with a secure grip on the unit to prevent dropping. The Side Grips™ are offered in a range of colors to aid in identifying departmental ownership. Available in Adult and Pediatric models, VeeVo® is the future of clinical suction.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Delivered flow rate reads off from a known reference.
Root cause: Internal orifice or float-tube wear.
Symptoms: Won't hold set pressure, audible gas leak.
Root cause: Diaphragm or seal degradation.
Symptoms: Stuck, misreading, or broken gauge needle/dial.
Root cause: Mechanical gauge movement wear.
Symptoms: Gas leak at a hose or cylinder connection.
Root cause: Worn O-ring or damaged threads.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace on any detected leak.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Fitting / connector O-rings Consumable - replace on any detected leak. | Periodic replacement | $ | Easy |
| Regulator / valve seal kit | Periodic replacement | $$ | Fairly easy |
| Flow tube / orifice assembly | Periodic replacement | $$ | Fairly easy |
| Pressure gauge | Major service part | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.