Syneron-Candela · Model GentleLASE
Speed - Treat more patients faster and more comfortably with the largest spot size and fastest repetition rate found on any hair removal laser. Efficacy - 17,666 watts of peak power enables the GentleLASE to treat a variety of conditions unlike any other laser on the market today. The GentleLASE is capable of delivering 755 nm fluences up to 100 J/cm2 in pulse durations of 3 ms for unparalleled treatment efficacies in hair removal - especially thinner, finer hairs other hair removal lasers simply cannot touch - and the treatment of pigmented and vascular lesions and wrinkles. Patient Comfort - Subject your patients to fewer laser pulses and provide them faster treatment times using the GentleLASE’s 18 mm spot size, the largest spot found on any hair removal laser. Patented Epidermal Cooling - Candela's Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort. Integrated computer controls assure consistent, reproducible protection, regardless of who is operating the laser for true treatment independence and ultimate patient safety.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Weak or no output at the delivery device, treatment ineffective, power not reaching the set value.
Root cause: Laser module / lamp / diode-bar ageing, a damaged delivery fibre / handpiece / applicator, or a driver / power-supply fault.
Symptoms: Unit shuts down after a period, over-temperature or low-flow alarm.
Root cause: Chiller / TEC fault, low or contaminated coolant, a failed pump, or blocked airflow.
Symptoms: Burn marks at the tip, high loss, intermittent output, applicator not recognised.
Root cause: Damaged or contaminated fibre / applicator / connector.
Symptoms: Skin cooling not delivered, cooling / cryogen alarm.
Root cause: Contact-cooling / cryogen supply, a valve, or the tip.
Symptoms: Laser will not fire, key / interlock / footswitch error.
Root cause: Footswitch, door interlock, or key-switch fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Power re-calibration required after replacement.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Laser module / lamp / diode bar Power re-calibration required after replacement. | Periodic replacement | $$$$ | Expert-level |
| Delivery fibre / handpiece / applicator | Frequent wear item | $$$ | Fairly easy |
| Chiller / TEC components & coolant filter | Periodic replacement | $$$ | Difficult |
| Contact-cooling tip / cryogen valve (aesthetic) | Periodic replacement | $$ | Moderate |
| Footswitch | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.