Stryker · Model Visum 300
Key advantages include: • 360 degrees of motion at three joints on the suspension with a single-point connection at the light head • 90 degrees vertical articulation • Easily accessible bulb may be changed without tools • Ergonomic, centrally located handle makes moving the light easy • Permanently mounted to the ceiling
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Fractured tip, loose component, debris.
Root cause: Metal fatigue, improper reprocessing, or misuse.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Potential incomplete final weld on the drop tube flange.
A change to the Preparation for Use section was identified where 2.5cc was replaced with 2cc-3cc volume and was not approved
Bur guards were distributed without an expiration date, and if they are used after they have expired it could result in the patient or operating room staff experiencing a burn or laceration.
A component of the device is a Dell laptop computer, which contains batteries that are under recall because they can overheat and cause a fire.
The device does not have an oblong hole for dynamic locking as required.