Stille-Sonesta · Model imagiQ2
True Free Float - empowering the surgeon to pan the table top with total precision & freedom of movement in any desired direction Low-dose enabler - high-performance carbon fiber table top with 0.4 mm Aluminum equivalence improves safety by enabling the C-arm to use less power, without compromising image quality Flexibility - retractable wheels for total stability and incredibly easy mobility out of the HOR Enhanced translucent length - total translucent length Enables the C-arm to generate outstanding images while reducing radiation dose Super slim design and retractable wheels enhance C-arm access, allowing the image receptor to be placed much closer to the patient in order to achieve images according to the A.L.A.R.A principle (As Low As Reasonably Achievable) Move the table top instead of the C-arm by using the True Free Float® technology, thus improving procedure time and efficiency in the OR
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →