Sony · Model LMD-2451MT 3D HD
Accuracy: Reveals clear and precise details. Multi-Purpose: Works in 2D or 3D formats. High Contrast: Improves 3D vision by providing better contrast Less Eye Fatigue: Includes built-in micropolarizer 3D filter, replacing the need for traditional 3D glasses with more comfortable lightweight, tinted glasses. Medical-Grade Certification: Complies with medical safety regulations in the O.R. Wide-Screen Display: Provides a larger view of the surgical field on a 24-inch screen. Multi-Modality Imaging Capability: Displays images from multiple sources on monitors. Consistent Color: Displays accurate color consistently on monitors and matches other Sony LMD monitors. Reveals color and texture variations not apparent through conventional SD technology. Stability: Produces stable and reliable image. Full WUXGA HD performance with 1920 x 1200 pixels 16:10 wide aspect ratio ChromaTru technology, assuring consistent color matching across multiple displays Two built-in option slots to select, expand, and change input/output signals for maximum flexibility Multipicture display including picture-outside-picture (POP) and side-by-side display for multiple image viewing 2D/3D switchable and may be used with both 2D and 3D camera systems.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: ECG, IBP, SpO2, temperature, CO2 or CO intermittently drops or is implausible.
Root cause: Worn patient cable / sensor, or a parameter-module / input-board fault.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer fault.
Symptoms: The host does not display a plugged-in module or a built-in parameter.
Root cause: Docking / connector fault or an internal board fault.
Symptoms: Blank, dim or distorted display; unresponsive touchscreen.
Root cause: Display, backlight, or controller fault.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack or a power-supply fault.
Symptoms: Monitor not shown at the central station, admit fails, intermittent drop.
Root cause: Wired / Wi-Fi network configuration or a communication board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| Parameter module / input board | Major service part | $$$ | Difficult |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Display / touchscreen assembly | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.