Smiths Medical · Model HL-90 Hotline
• Keeps blood and fluids warm, between 37 - 42°C, delivering warm fluids to the patient at flow rates up to 5000 ml/hr • Outperforms hotplate technologies in 91% of surgical procedures • Easy to use: less time to set up and easy to disconnect from the patient • Once-a-year reservoir maintenance protocol compared to hotplate warmers, which may require maintenance up to 12 times per year
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No heat, or overheat alarm.
Root cause: Heater element or thermal cutoff failure.
Symptoms: Delivered fluid temperature out of set range.
Root cause: Inline/probe sensor aging or miscalibration.
Symptoms: False or missed air-in-line alerts.
Root cause: Air detector sensor drift or dirty optics.
Symptoms: Fluid leak, or won't prime.
Root cause: Worn cassette/tubing seat or cracked fitting.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable in some designs.
Safety-critical; verify at PM.
Single-use consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Heating element / plate | Periodic replacement | $$$ | Moderate |
| Temperature sensor / probe Consumable in some designs. | Periodic replacement | $$ | Fairly easy |
| Air-in-line sensor Safety-critical; verify at PM. | Major service part | $$$ | Moderate |
| Disposable tubing / cassette set Single-use consumable. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
HOTLINE Blood and Fluid Warmers included Greek and Danish language labeling instead of the required Finnish labeling.
Injection port of the Set may leak blood/ IV fluids from the septum of the injection port or the septum may become dislodged.
HOTLINE 3 Blood and Fluid Warmer( Reorder No. HL-390 ) disposable is not correctly installed , the microswitch may become damaged and unusable
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.